Menu Career Language: EN/DE

PA6 – Polyamide 6 PA6

AKROMID® B3 3 natural (5772)

AKROMID® B3 3 natural (5772) is an unreinforced polyamide 6.

The material is a nucleated and lubricated dryblend, that can be used to achive short injection moulding cycles. It is suitable for thin wall drawer slides, cable glands and application in the auomotive sector.

Properties

Tensile Modulus
Tensile Strength
Impact Strength

Features

nucleated
industrial
  • Mechanical Properties

    Tensile modulus (1 mm/min | ISO 527-2) d.a.m. 3200 MPa

    Stress at yield (50 mm/min | ISO 527-2) d.a.m. 80 MPa

    Strain at yield (50 mm/min | ISO 527-2) d.a.m. 4 %

    Strain at break (50 mm/min | ISO 527-2) d.a.m. 20 %

  • Thermal Properties

    Melting temperature (DSC, 10K/min | DIN EN ISO 11357-3) 220 °C

  • Flammability

    Burning rate (UL 94)
    1,6mm Wall thickness HB Class

    Burning rate (<100 mm/min) (> 1 mm Thickness | FMVSS 302) +

  • General properties

    Density (23°C | ISO 1183) 1,13 g/cm³

    Molding shrinkage (flow | ISO 294-4) 1,0-1,2 %

    Molding shrinkage (transverse | ISO 294-4) 1,1-1,3 %

Processing information

The listed values are recommendations. Higher values should be used for higher glass loadings. We recommend only de-humidifying or vacuum dryers. Extensive drying can cause filling problems and surface defects.


6 Drying time 0 - 4 h

Drying temperature (τ ≤ -30°C) 80°C

Processing moisture 0,02 - 0,1%

1 Feed section 60 - 80°C

2 Temperature zone 1 - Zone 4 220 - 270°C

3 Nozzle temperature 230 - 300°C

4 Melt temperature 240 - 270°C

5 Mold temperature 40 - 80°C

P Nach Holding pressure, spec. 300 - 800 bar

P Stau Back pressure, spec. 50 - 150 bar

Injection speed medium to high

Screw speed 8 - 15 m/min

Disclaimer

All specifications and information given on this website are based on our current knowledge and experience. A legally binding promise of certain characteristics or suitability for a concrete individual case cannot be derived from this information. The information supplied here is not intended to release processors and users from the responsibility of carrying out their own tests and inspections in each concrete individual case. AKRO®, AKROMID®, AKROLEN®, AKROLOY®, AKROTEK®, ICX® and PRECITE® are registered trademarks of the Feddersen Group.

Measuring Curves

AKROMID® A, B, C Engineering Thermoplastic

 

More about AKROMID®

Notes

salt and pepper dry blend with lubrication and nucleation natural color is not specified and may vary

“d.a.m.” = dry as moulded test values = residual moisture content <0.1%