PA5.10 – Polyamide 5.10 PA5.10 GF30
AKROMID® NEXT 5.10 3 GF 30 natural (8406)The biobased AKROMID® NEXT 5.10 3 GF 30 natural (8406) is a HMD-free (hexamethylenediamine) alternative to PA 6.10. With 30% glass fibre reinforcement, the material is suitable for components with high strength requirements.
Properties
Tensile Modulus Tensile Strength Impact StrengthFeatures
-
Mechanical Properties
Tensile modulus (1 mm/min | ISO 527-2) d.a.m. 8300 MPa conditioned 6000 MPa
Stress at break (5 mm/min | ISO 527-2) d.a.m. 160 MPa conditioned 120 MPa
Strain at break (5 mm/min | ISO 527-2) d.a.m. 3,2 % conditioned 4,5 %
Charpy impact strength (23°C | ISO 179-1/1eU) d.a.m. 72 kJ/m² conditioned 74 kJ/m²
Charpy notched impact strength (23°C | ISO 179-1/1eA) d.a.m. 13 kJ/m² conditioned 14 kJ/m²
-
Thermal Properties
Temperature of deflection under load HDT/A (1,8 MPa | ISO 75) 194 °C
Melting temperature (DSC, 10K/min | DIN EN ISO 11357-3) 217 °C
-
General properties
Density (23°C | ISO 1183) 1,29 g/cm³
Humidity absorption (70°C, 62% r.H. | ISO 1110) 1,2 %
-
Sustainability
Biobased carbon content info_outline (calculated) 97 %
Processing information
The listed values are recommendations. Higher values should be used for higher glass loadings. We recommend only de-humidifying or vacuum dryers. Extensive drying can cause filling problems and surface defects.
Drying time | 0 - 4 h | |
Drying temperature (τ ≤ -30°C) | 80°C | |
Processing moisture | 0,02 - 0,1% | |
Feed section | 60 - 80°C | |
Temperature zone 1 - Zone 4 | 240 - 290°C | |
Nozzle temperature | 260 - 300°C | |
Melt temperature | 270 - 290°C | |
Mold temperature | 80 - 100°C | |
Holding pressure, spec. | 300 - 800 bar | |
Back pressure, spec. | 50 - 150 bar | |
Injection speed | medium to high | |
Screw speed | 8 - 15 m/min | |
Disclaimer
All specifications and information given on this website are based on our current knowledge and experience. A legally binding promise of certain characteristics or suitability for a concrete individual case cannot be derived from this information. The information supplied here is not intended to release processors and users from the responsibility of carrying out their own tests and inspections in each concrete individual case. AKRO®, AKROMID®, AKROLEN®, AKROLOY®, AKROTEK®, ICX® and PRECITE® are registered trademarks of the Feddersen Group.