PA6 – Polyamide 6 PA6 CF10
AKROMID® B3 ICF 10 9 black (7220)AKROMID® B3 ICF 10 9 black (7220) is a 10% carbon fibre reinforced, heat stabilised and process optimised polyamide 6.
Properties
Tensile Modulus Tensile Strength Impact StrengthFeatures
-
Mechanical Properties
Tensile modulus (1 mm/min | ISO 527-2) d.a.m. 7600 MPa
Stress at break (5 mm/min | ISO 527-2) d.a.m. 120 MPa
Strain at break (5 mm/min | ISO 527-2) d.a.m. 3,0 %
Flexural modulus (2 mm/min | ISO 178) d.a.m. 7000 MPa
Charpy impact strength (23°C | ISO 179-1/1eU) d.a.m. 35 kJ/m²
Charpy notched impact strength (23°C | ISO 179-1/1eA) d.a.m. 4 kJ/m²
-
Thermal Properties
Temperature of deflection under load HDT/A (1,8 MPa | ISO 75) 190 °C
Melting temperature (DSC, 10K/min | DIN EN ISO 11357-3) 220 °C
-
Flammability
Burning rate (UL 94) 1,6mm Wall thickness HB Class
Burning rate (<100 mm/min) (> 1 mm Thickness | FMVSS 302) +
-
General properties
Density (23°C | ISO 1183) 1,17 g/cm³
Molding shrinkage (flow | ISO 294-4) 0,3 - 0,5 %
Molding shrinkage (transverse | ISO 294-4) 0,6 - 0,8 %
-
Rheological Properties
Flowability (1mm Thickness | AKRO) 210 mm
-
Sustainability
Recycled content (at least) 10 %
Processing information
The listed values are recommendations. Higher values should be used for higher glass loadings. We recommend only de-humidifying or vacuum dryers. Extensive drying can cause filling problems and surface defects.
Drying time | 0 - 4 h | |
Drying temperature (τ ≤ -30°C) | 80°C | |
Processing moisture | 0,02 - 0,1% | |
Feed section | 60 - 80°C | |
Temperature zone 1 - Zone 4 | 240 - 300°C | |
Nozzle temperature | 270 - 300°C | |
Melt temperature | 270 - 300°C | |
Mold temperature | 80 - 130°C | |
Holding pressure, spec. | 300 - 800 bar | |
Back pressure, spec. | 50 - 150 bar | |
Injection speed | medium to high | |
Screw speed | 8 - 15 m/min | |
Disclaimer
All specifications and information given on this website are based on our current knowledge and experience. A legally binding promise of certain characteristics or suitability for a concrete individual case cannot be derived from this information. The information supplied here is not intended to release processors and users from the responsibility of carrying out their own tests and inspections in each concrete individual case. AKRO®, AKROMID®, AKROLEN®, AKROLOY®, AKROTEK®, ICX® and PRECITE® are registered trademarks of the Feddersen Group.