PA6.6 – Polyamide 6.6 PA66 + PA6I/6T GF60
AKROLOY® PA GF 60 natural (6465)AKROLOY® PA GF 60 natural (6465) is a 60% glass fibre reinforced, semi-aromatic polyamide-blend with very high stiffness and strength, even in conditioned state.
Properties
Tensile Modulus Tensile Strength Impact Strength-
Mechanical Properties
Tensile modulus (1 mm/min | ISO 527-2) d.a.m. 21000 MPa conditioned 20000 MPa
Stress at break (5 mm/min | ISO 527-2) d.a.m. 280 MPa conditioned 230 MPa
Strain at break (5 mm/min | ISO 527-2) d.a.m. 2,4 % conditioned 2,4 %
Charpy impact strength (23°C | ISO 179-1/1eU) d.a.m. 100 kJ/m² conditioned 100 kJ/m²
Charpy notched impact strength (23°C | ISO 179-1/1eA) d.a.m. 19 kJ/m² conditioned 19 kJ/m²
-
Thermal Properties
Temperature of deflection under load HDT/A (1,8 MPa | ISO 75) 245 °C
Temperature of deflection under load HDT/C (8 MPa | ISO 75) 193 °C
Melting temperature (DSC, 10K/min | DIN EN ISO 11357-3) 255 °C
-
Flammability
Burning rate (UL 94) 1,6mm Wall thickness HB Class
Burning rate (<100 mm/min) (> 1 mm Thickness | FMVSS 302) +
-
General properties
Density (23°C | ISO 1183) 1,72 g/cm³
Humidity absorption (70°C, 62% r.H. | ISO 1110) 1,1 %
Processing information
The listed values are recommendations. Higher values should be used for higher glass loadings. We recommend only de-humidifying or vacuum dryers. Extensive drying can cause filling problems and surface defects.
Drying time | 0 - 4 h | |
Drying temperature (τ ≤ -30°C) | 80°C | |
Processing moisture | 0,02 - 0,1% | |
Feed section | 60 - 80°C | |
Temperature zone 1 - Zone 4 | 260 - 300°C | |
Nozzle temperature | 270 - 300°C | |
Melt temperature | 280 - 300°C | |
Mold temperature | 90 - 130°C | |
Holding pressure, spec. | 300 - 800 bar | |
Back pressure, spec. | 50 - 150 bar | |
Injection speed | medium to high | |
Screw speed | 8 - 15 m/min | |
Disclaimer
All specifications and information given on this website are based on our current knowledge and experience. A legally binding promise of certain characteristics or suitability for a concrete individual case cannot be derived from this information. The information supplied here is not intended to release processors and users from the responsibility of carrying out their own tests and inspections in each concrete individual case. AKRO®, AKROMID®, AKROLEN®, AKROLOY®, AKROTEK®, ICX® and PRECITE® are registered trademarks of the Feddersen Group.