Menu Career Languages: EN/DE/PT
Preliminary datasheet

PA6 – Polyamide 6 PA6 + X GF60

AKROMID® B3 GF 60 4 RM-M natural (4645)

21500 MPa

235 MPa

65 kJ/m²

AKROMID® B3 GF 60 4 RM-M natural (4645) is a 60% glass fiber reinforced, hydrolysis- and chemical stabilised polyamide 6 with low humidity absorption, very good surface finish and light inherent color.

Typical applications

Housings and other dimensional stable parts in the automotive and electronic industry demanding high resistance against CaCl2-solvents, as well as a very good surface.

Processing information

The listed values are recommendations. Higher values should be used for higher glass loadings. We recommend only de-humidifying or vacuum dryers. Extensive drying can cause filling problems and surface defects.


6Drying time0 - 4 h

Drying temperature (τ ≤ -30°C)80°C

Processing moisture0,02 - 0,1%

1Feed section60 - 80°C

2Temperature zone 1 - Zone 4220 - 290°C

3Nozzle temperature240 - 300°C

4Melting temperature240 - 290°C

5Mold temperature80 - 100°C

P NachHolding pressure, spec.300 - 800 bar

P StauBack pressure, spec.50 - 150 bar

Injection speedmedium to high

Screw speed8 - 15 m/min

  • Mechanical Properties
    Tensile modulus (1 mm/min | ISO 527-2)
    d.a.m.21500 MPa
    conditioned17000 MPa

    Stress at break (5 mm/min | ISO 527-2)
    d.a.m.235 MPa
    conditioned175 MPa

    Strain at break (5 mm/min | ISO 527-2)
    d.a.m.2 %
    conditioned2,7 %

    Flexural modulus (2 mm/min | ISO 178)
    d.a.m.20500 MPa

    Flexural strength (2 mm/min | ISO 178)
    d.a.m.350 MPa

    Charpy impact strength (23°C | ISO 179-1/1eU)
    d.a.m.65 kJ/m²
    conditioned65 kJ/m²

  • Thermal Properties
    Melting temperature (DSC, 10K/min | DIN EN 11357-1)225 °C

  • Flammability
    Burning rate (UL 94)
    0,8mm Wall thicknessHB Class

    Burning rate (<100 mm/min) (> 1 mm Thickness | FMVSS 302) +

  • General properties
    Humidity absorption (70°C, 62% r.F. | ISO 1110)1,05 %

  • Electrical Properties
    Comparative tracking index (Test liquid A | IEC 60112)600 V

Disclaimer

All specifications and information given on this website are based on our current knowledge and experience. A legally binding promise of certain characteristics or suitability for a concrete individual case cannot be derived from this information. The information supplied here is not intended to release processors and users from the responsibility of carrying out their own tests and inspections in each concrete individual case. AKRO®, AKROMID®, AKROLEN®, AKROLOY®, AKROTEK®, ICX® and PRECITE® are registered trademarks of the Feddersen Group.